• Kyn28-24medium Voltage Ring Main Unit
  • Kyn28-24medium Voltage Ring Main Unit
  • Kyn28-24medium Voltage Ring Main Unit
  • Kyn28-24medium Voltage Ring Main Unit
  • Kyn28-24medium Voltage Ring Main Unit

Kyn28-24medium Voltage Ring Main Unit

Certification: VDE, CCC, ISO9001
Shell Material: Aluminum Alloy
Voltage Level: Low Voltage
Installation: Fixed
Structure: Withdrawable
Current: DC
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Zhejiang, China
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
ODM Services
The supplier provides ODM services
OEM Services
The supplier provides OEM services for popular brands
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (23)
  • Overview
  • Product Parameters
  • Company Profile
  • Felds of Application
  • Certifications
  • Delivery
  • FAQ
Overview

Basic Info.

Model NO.
KYN28-24
Size
500
Voltage
380, 400, 660
Product Name
Gck
Application
Electric Power Transmission
MOQ
1 Piece
Rated Voltage
380V, 400V, 660V
Trademark
GGAOE
Origin
Zhejiang, China
HS Code
7201500010
Production Capacity
100000 Piece/Pieces Per Month

Product Description

Product Parameters

 
 Kyn28-24medium Voltage Ring Main Unit
product name Ring Main Unit
rated voltage 12KV
Rated current 630A
Rated frequency 50HZ
protection grade Three station SF6 load switch, operating mechanism with mechanicalposition indication device, interlocking device, integrated low-voltageroom,relay protection device, busbar room shell
Middle unit Circuit breaker room, Vsl type orvD4/s type lsM type wacuum circuitbreaker or HD4/S type SF6 circuit breaker
lower unit Grounding busbar , Cable compartment shell , Cable compartmentbottom plate with cable support components
   
working conditions:
Environmental temperature: maximum temperature+50 °C,minimum temperature -40'C, maximum daily averagetemperature not exceeding 35 °C;
Relative humidity: The daily average value does not exceed 95%and the monthly average value does not exceed 90%;
Wind speed: not exceeding 35m/s;
Pollution level: Level ll;
Earthquake intensity: 8 degrees;
Ground inclination: no more than 3 degrees;
Installation location: Install in a place without fire,explosion, orsevere vibration, with good ventilation, and without corrosivegases.
Special conditions:
When the equipment is installed at an altitude of over 1000meters, specialinstructions should be given so that the companycan adjust the SF6 pressure during manufacturing.
If there are special and harsh conditions involved, please be sureto consult the company.
 
 
Kyn28-24medium Voltage Ring Main UnitKyn28-24medium Voltage Ring Main UnitKyn28-24medium Voltage Ring Main UnitKyn28-24medium Voltage Ring Main UnitKyn28-24medium Voltage Ring Main UnitKyn28-24medium Voltage Ring Main UnitKyn28-24medium Voltage Ring Main Unit

Company Profile

We have established a sound quality management system, and have passed the certification of ISO9001:2015 quality management system, ISO14001:2015 environmental management system, and ISO45001:2018 occupational health and safety management system.

In order to ensure product quality and in order to meet the development and supply of our dry-type transformers in overseas international markets, we all participate in type and special tests of internationally recognized independent testing laboratories, and obtain relevant reports.

Since the 1950s,the development of medium voltage switchgearhas gone through stages such as open type, box type, and metalenclosed type, and there is no longer any room forimprovement inmeeting the functional usage requirements of the equipment What'sthe problem, and the product has already been serialized and fullycovered in its usage range. The rapid development ofenvironmentallyfriendly gas insulated ring main units with small size, maintenancefree, high modularity, and safety reliability can achieve remote moni-toring, control, and management of the power system distributionnetwork, meeting the needs of power grid optimization, electricitysafety,energy management,and energy conservation and consump-tion reduction, The system can be widely used in intelligent power dis-tribution fields such as transportation, factories, hospitals, schools,buildings, residential communities, and commercial office buildings

Kyn28-24medium Voltage Ring Main Unit

Felds of Application

Kyn28-24medium Voltage Ring Main Unit
Kyn28-24medium Voltage Ring Main Unit
 
Kyn28-24medium Voltage Ring Main Unit

Certifications

Kyn28-24medium Voltage Ring Main Unit

Delivery

Kyn28-24medium Voltage Ring Main Unit
Kyn28-24medium Voltage Ring Main Unit

FAQ

Q:what's your major products?
A: oil immersed transformer, dry type transformer, Transformer Substation, High and Low Voltage Switchgear


Q: Can your product be customized?
A: Considering differences in voltage, frequency and other special transformer product in different countries and regions, our product can be customized according to your requirements.

Q: When can I get the price?
A:Usually we quote within 24 hours after we get your inquiry.

Q: What about lead or shipping time?
A: The lead time depends on the quantity you ordered, generally within 15 days upon receipt of advance payment.

Q: What is the price of shipping?
A: Depending upon the port of delivery, prices varies.

Q: Do you offer guarantee for the products?
A: Yes. We offer at least one years guarantee for all of our transformers.


Q: Your Advantage?
A: 15 years experience, Advanced production equipment, Stable quality, Fast delivery, Professional & good & Prompt service. Also some free parts can be provided for you.
Note:
The following technical information should be provided when placing an order: Main wiring scheme number, purpose and single line system diagram, rated voltage and rated current rated short-circuit breaking current/distribution room layout plan and arrangement and configuration diagram of switchgear;
Requirements for control measurement and protection functions of switchgear, as well as requirements and schematic diagrams for other interlocking and automatic devices;
The models specifications and quantities of the main electrical components inside the switchgear;
When the switchgear is used in special environmental conditions; detailed instructions should be provided when placing an order;

 