Certification: | CCC, ISO9001 |
---|---|
Shell Material: | Steel Plate |
Voltage Level: | Medium Voltage |
Installation: | Removable |
Structure: | Cabinet |
Current: | AC |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Technical Sheet:
(It can be customized according to customer's local demand!)
Rated Power (kVA) |
High Voltage (kV) |
H.V. Tap range |
Low Voltage (kV) |
Connection symbol |
Short Circuit Impendence (%) |
No-load loss (W) |
On-load loss (W) |
No load current (%) |
||||
S9 |
S10 |
S11 |
S9 |
S10 |
S11 |
|||||||
800 |
35 38.5 |
±3x2.5% |
6.3 6.6 10 10.5 11 |
Yd11 YNd11 |
6.5 |
1320 |
1190 |
1060 |
10500 |
9980 |
9980 |
1.05 |
1000 |
1570 |
1410 |
1260 |
12800 |
12160 |
12160 |
1 |
|||||
1250 |
1860 |
1670 |
1490 |
15400 |
14630 |
14630 |
0.9 |
|||||
1600 |
2250 |
2030 |
1800 |
18500 |
17580 |
17580 |
0.85 |
|||||
2000 |
2880 |
2590 |
2300 |
20250 |
19240 |
19240 |
0.8 |
|||||
2500 |
3400 |
3060 |
2720 |
21730 |
20640 |
20640 |
0.8 |
|||||
3150 |
7 |
4040 |
3640 |
3230 |
26010 |
24710 |
24710 |
0.72 |
||||
4000 |
4840 |
4360 |
3870 |
30690 |
29160 |
29160 |
0.72 |
|||||
5000 |
5800 |
5220 |
4640 |
36000 |
34200 |
34200 |
0.68 |
|||||
6300 |
7.5 |
7040 |
6340 |
5630 |
38700 |
36770 |
36770 |
0.68 |
||||
8000 |
9840 |
8860 |
7870 |
42750 |
40610 |
40610 |
0.6 |
|||||
10000 |
11600 |
10440 |
9280 |
50580 |
48050 |
48050 |
0.6 |
|||||
12500 |
8 |
13680 |
12310 |
10940 |
59850 |
56860 |
56860 |
0.56 |
||||
16000 |
16460 |
14810 |
13170 |
74020 |
70320 |
70320 |
0.54 |
|||||
20000 |
19460 |
17510 |
15570 |
87140 |
82780 |
82780 |
0.54 |
|||||
25000 |
23700 |
21330 |
18960 |
107000 |
101650 |
101650 |
0.5 |
|||||
31500 |
27500 |
24750 |
22000 |
126000 |
119700 |
119700 |
0.45 |
Pre-sales
We provide technical support and complete power distribution solutions tailored to your needs. If the design drawings you provide are deemed unfeasible, we will optimize the plan and adjust it with the dimensions of the cabinet, the location of the equipment, and so on. We will also optimize the configuration of the products to make them meet your requirements.
After-Sales
If any problem occurs, we will first provide support by phone or email. We will perform a remote debug if necessary. Furthermore, our products come with a troubleshooting manual for reference when trying to find the fault and solve issues by yourself. Most problems can be solved by the above-mentioned methods. We will check in every year or so to acquire detailed information about your equipment to get a better understanding of the inner workings.
Our customer service promise
1. We will quickly solve the problem after receiving the issue report or repair request.
2. We then explain the cause of failure in detail and any fees will be charged according to market pricing.
3. If we take any parts back for inspecting, we will apply fragile notice stickers on them or write their serial number down to maintain the safety of the parts.
4. If your complaint is deemed valid, we will refund repair fees to you on-site.
Product Introduction:
The S11-M fully sealed distribution transformer uses high-qualityhigh magnetic orientation silicon steel sheets as its iron core. Afteroptimization design, the no-load loss is reduced by about 30% onaverage compared to the Sll type.lt is currently a new energy-savingproduct second only to the S (B) H15 type amorphous alloy trans-former and has a high cost-effectiveness. Suitable for power plants(stations),substations (distribution stations), as well as industrial,commercial, construction and other fields.lmplement national stan.dards such as GB1094 and GB20052
working conditions:
GB1094.1-2013 Power Transformers Part 1G1094.2-2013 Power Transformers Part 2GB1094.3-2003 Power Transformers Part 3
GB/1094.5-2008 Power Transformers Part 5
GB/T6451-2015 Technical parameters and requirements for three-phase oilimmersed power transformers
GB/T25289-2010Technical parameters and requirements for 20K\oil immersed distribution transformers International
Standard lEC76
We have established a sound quality management system, and have passed the certification of ISO9001:2015 quality management system, ISO14001:2015 environmental management system, and ISO45001:2018 occupational health and safety management system.
Note:
The following technical information should be provided when placing an order: Main wiring scheme number, purpose and single line system diagram, rated voltage and rated current rated short-circuit breaking current/distribution room layout plan and arrangement and configuration diagram of switchgear;
Requirements for control measurement and protection functions of switchgear, as well as requirements and schematic diagrams for other interlocking and automatic devices;
The models specifications and quantities of the main electrical components inside the switchgear;
When the switchgear is used in special environmental conditions; detailed instructions should be provided when placing an order;
Suppliers with verified business licenses